49
9 Technical data
9 Technical data
Voltage 220–240V~, 50Hz
Power 1450W
Conformity mark
A S
Energy consumption
‘Save energy’ / ‘Active
approx. 6Wh
Energy consumption
‘Save energy’ / ‘Inactive
approx. 13Wh
Pump pressure static, max. 15bar
Holding capacity of water tank 1.9l
Holding capacity of bean container 310g
Holding capacity of coffee grounds
container
max. 15 portions
Cable length approx. 1.1m
Weight approx. 9.6kg
Dimensions (W×H×D) 28.5 × 35.5 × 44.5cm
Information for testers (repeat test in accordance with DIN VDE
0701-0702): The central grounding point (CGP) is located on the
underside of the machine, right next to the mains cable's connec-
tion point.